1 Product overview
We do not recommend using a remote control in an ambiSENSE zone.
Install the ambiSENSE components in the control room that has the highest desired temperatures.
1.2
Influence on the system control
ambiSENSE can be used with the VRC 700 system control (all generations) or the VRC 720 system control. The heating
circuit that is controlled by ambiSENSE is automatically set to the "Day mode" (VRC 700) or "Manual" (VRC 720) operating
mode. The maximum target temperature for all rooms is forwarded to the system control. The heat demand control is adjus-
ted via the boiler. If the target temperatures of all of the rooms that are controlled by ambiSENSE are reached, the heating
circuit that is controlled by ambiSENSE is automatically set to "Off" in order to save energy. If ambiSENSE is activated, the
time programmes and target temperatures for the heating circuit that are displayed on the system control are no longer valid
and are overwritten every 15 minutes. Time programmes and target values for the heating circuit can be individually set for
each individual room using the app.
8
Operating instructions 0020257208_01