Manual cleaning
If the suction power decreases, cleaning
can be started manually by turning the
switch [1-9] to the AC symbol positioned on ei
ther side of the switch.
We recommend cleaning the main filter com
pletely if severely clogged:
► Set the suction power adjuster [1-8] to the
maximum setting.
► Cover the end of the nozzle or suction hose
with your hand for 10 seconds.
► Turn the switch [1-9] to the AC symbol.
When the CT-VS closing slide is used (or
der no.: 497926), the filter can be cleaned
fully without removing the connected elec
tric power tools.
In intensive applications that generate adherent
dust, it may be necessary to clean the filter ele
ment mechanically under certain circumstan
ces (extract). Wear a dust mask!
8.7
Applying the brake
Folding out the brake lever [1-13] prevents the
mobile dust extractor from rolling. To achieve
this, lift the front end of the mobile dust extrac
tor slightly and push the brake lever down
wards until it latches into place. Push the lev
er [1-12] again to release.
9
Working
9.1
Handling
Hose store: after finisching work, you can feed
the suction hose through the recess [4-2] and
place it in the hose store.
SysDoc Systainer attachment system: a
Systainer can be attached to the storeage area
via the four slides ore the T-Loc [4-1] .
4
4-2
4-1
9.2
Extracting dry materials
Hazardous dust
Damage to the respiratory passage
► Use a filter or disposal bag when extracting
hazardous materials!
► Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room, the air renewal rate L within the room
must be sufficient. The volume of air dis
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
x air renewal rate L
R
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
9.3
Extracting fluids
Risk of injury
► Do not evacuate combustible liquids!
The main filter shall only be used for ex
tracting dry materials.
Before extracting fluids, remove the filter bag
(see chapter 10.1). We recommend using a
special wet filter.
The dust extractor stops automatically when
the maximum level is reached.
Escaping foam and fluids
► Switch off the machine immediately and
empty the dust container.
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
4-1
9.4
Special features of the CT 36 E AC- LHS
To use the mobile dust extractor in combination
with the PLANEX:
CAUTION
). Observe all the rele
W
WARNING
CAUTION
CAUTION
English
13