5.2 OVEN INSTALLATION SITE

The figure below shows the minimum distances that must
be respected when positioning the oven in order to make
using, cleaning and maintaining the oven easier, in
addition to allowing for proper ventilation.
Keep a distance of at least 25 cm between the oven and
the room's side walls, and where possible, leave at least
50 cm on the right side so that the electrical system can
easily be accessed for maintenance and/or repairs. Leave
a gap of at least 50 cm from the back wall.

6. INSTALLATION (chapter for the installer technician)

This chapter is exclusively dedicated to the installer technician installing the appliance.
All operations indicated in this chapter are not the responsibility of the user, and therefore,
the user must under no circumstances carry out the operations, measurements and adjustments
indicated here. Any operation performed by unauthorised personnel will be considered as
product tampering and therefore the liability for any malfunctions or worse (e.g. accidents and/or
damage), will fall on those who performed these operations.
The installation must be carried out by qualified personnel in accordance with the local, national and European
regulations.

6.1 POSITIONING THE OVEN

Make sure that the oven's support surface has an adequate load-bearing
capacity, is level and is made of non-combustible materials (steel, marble,
etc.). Check that the underlying compartment does not contain flammable
materials (such as liquids) or gas cylinders. Inform the user of this safety
warning.
After the oven has been removed from its special packaging, position it where
desired whilst taking the minimum distances into account (see point 4.2).
Remove any polystyrene protections and the protective film (F) without using tools that could damage the
surfaces.

6.2 CONNECTION TO THE UTILITIES

6.2.1

Electrical connection

When connecting the appliance electrically, a differential magnetothermic switch with suitable characteristics
must be interposed, with an opening distance between the contacts of at least 3 mm. To connect the oven
electrically simply connect the plug on the provided electrical cable.
The electrical outlet must be easy to access, no moving should be necessary.
The electrical connection (plug) must be easily accessible, also following oven
installation.
!
The distance between the machine and the socket must be adequate to not cause tension in the
power supply cable. In addition, the cable must not be located beneath the machine support
base.
If the power supply cable has been damaged, it must be replaced by the technical
!
assistance service or by a qualified technician to prevent any risks.