User manual - English
5 Installation and commissioning
! CAUTION:
When working on or inside the machine, note that the sheet metal parts used are sometimes sharp-edged
and you can injure yourself. Wear suitable protective gloves!
Follow the instructions below during assembly and installation to ensure optimum functioning of the ice cu-
be maker:
Assembly
5.1
Make sure that the installation site is firm and level and that there is good ventilation.
The installation area must withstand the weight loads.
The installation height should be at least 100 mm above the drain or funnel siphon.
Do not sit or stand on the ice maker! Do not place any objects on the device!
Do not lift the ice maker by the ice removal flap!
ADVICE:
Under certain environmental conditions (e.g. high ambient temperature and / or high air humidity) conden-
sation can form in the area of the ice maker.
The ice cube maker must not be operated in the following environments:
•
atmosphere subject to explosion hazard,
•
toxic atmosphere,
•
damp rooms.
Direct heat sources such as ovens, dishwashers etc. will impair the performance of the ice cube maker and
increase the cleaning effort and energy consumption.
! CAUTION
Always handle the box or the unpacked device or the individual modules in pairs!
5.2 Installation
Please note the connection diagrams during installation work!
1. For CL / CW and ECL / ECW models, attach the ice maker module to the combi or crusher module with
two M5 x 15 screws.
2. To ensure that the machine functions optimally, the ice maker must be horizontal from left to right. From
the front to the back it must have a slight gradient of max. 10 mm. The adjustable feet included in the deliv-
ery can be used for alignment.
User-manual-CombiLine-W80-W120-W240-0299-2