Maintenance And Inspection - ALFRA TML 100 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Maintenance and inspection of the lifting magnet
The user is obliged to maintain and service the lifting magnet in compliance with the specifications in the operating
manual and according to the country-specific standards and regulations (e.g. ASME B30.20B, DGUV-Information
209-013; AMVO).
The maintenance intervals are classified according to the recommended schedule. If one of the faults listed should
occur, please proceed as follows:
Beforeeveryuse...
visually inspect the lifting magnet for damage
clean the surface of the workpiece and the underside of the magnet
free the underside of the magnet of rust, chips or unevenness
Weekly...
inspectthe lifting magnet for deformation, cracks or other defects
make sure the activation lever is working properly and latches correctly into place
inspect the load swivel for damage, deformation, cracks or wear and have it replaced if necessary
inspect the bottom of the magnet for scratches, pressure points or cracks and have the magnet repaired by
the manufacturer if necessary
Monthly...
check the markings and labelling on the lifting magnet for legibility and damage and replace them if
necessary
Annually...
have the load-bearing capacity of the lifting magnet checked by the supplier or an authorised workshop
An annual inspection is recommended for the triple safety system of this lifting magnet. We will be glad to assume
this inspection for you first-hand. Please send us an email to:
You will then promptly receive an offer and have the assurance that the lifting magnet will be inspected in a
process-reliable manner where it was actually produced.
Unauthorised repairs or modification to the lifting magnet are not permitted.
If you have any questions contact the manufacturer.