Technical data
4x screws with raised head for installation
1x manual
Technical data
Product name
Item number
Compatible equipment
Environmental class
Protection class, IP pro-
tection class
Operating temperature
Humidity, maximum
Housing material
Dimensions – sensor
Dimensions – magnet
Weight – sensor
Weight – Magnet
Security level
Tamper monitoring
Tamper protection
Displays
Connections
Type of power supply
Power consumption/en-
ergy consumption
Operating voltage
Battery type
Battery life
Battery under voltage
threshold
Voltage monitoring
16 |
EN
Secvest Small Wireless Magnetic Contact
FUMK50031W
868 MHz narrow band receiver from ABUS
II (EN 50131-1 + A1:2009 Section 7)
IP34 (internal spaces, in its installed state)
IP = international protection or ingress protection
3 = tools and wires
4 = splashing water
-10°C to +55°C
Non-condensing average relative humidity 75%
PC/ABS
19 x 103 x 24 mm (WxHxD)
12 x 55 x 12 mm (WxHxD)
40 g (with battery)
30 g without battery, 10 g battery only
10 g
2 (EN 50131-1 + A1:2009 Section 6)
yes
according to EN50131-2-6 Section 4.5
1 LED
trigger signalling, for infrared programming
Jumper to deactivate the front LED
Plug-in terminal
Type C (EN 50131-1 Section 9 and EN 50131-6 Section 4.1)
Power supply compliant with EN50131-1:2006+A1:2009 9.2 and
EN50131-6 if installed correctly together with Secvest FUAA50xxx.
3 µA standby current
35 mA max.
3 V DC
1x CR2 battery, 3V, lithium LiMn02
Replacement battery FU2990
Typically > 2 years
2.4 V, 'Flat battery' fault at < 2.4 V
During operation the voltage provided by the battery is monitored. If
the voltage is below the lower threshold of 2.4 V, a fault report is
sent to the alarm control panel and the user is informed.