Step 1: Select installation location for the detector
Select an installation location which:
 is within the wireless range of the alarm panel or the wireless-receiver (max. 500 m out-
doors).
The wireless signal strength of the detector should be tested at the installation loca-
tion of the alarm panel prior to installation.
Note
The wireless range can be shortened when the sensor is mounted on or near a
metal surface.
The detector must not be installed in the following locations:
 at a distance of less than 1 m from household electrical systems or power
Note
distributors
 inside metal housings
 close to high-voltage devices or electronic devices such as computers, photo-
copiers or other wireless devices.
The sensor should be mounted at the top, preferably on the stationary part of the door or window
frame. This ensures consistent transmission power during operation.
The spacers that are included within the scope of delivery can be mounted behind the magnet or
the sensor. The detector must not be installed on the hinge-side.
Sensor and magnet can also be positioned opposite each other, as long as:
 the arrows on the back plates of sensor and magnet are aligned with each other
 the maximum distance between the front covers does not exceed 10 mm when mounted on
a metal surface or 15 mm when mounted on a non-metallic surface.
The magnet can be mounted on the right or the left side of the sensor.
Note
Step 2: Open the cover of sensor and magnet
 Remove the screw from the underside of the sensor and open the cover.
 Use a suitable slotted screwdriver and open the cover of the magnet.
Installation
19 |