Description
Th e DC 5800TR is a machine with large suction capacity
and robust construction while still being compact and easy
to maneuver.
It is ideal for spot extraction on most types of hand-held
tools and for industrial cleaning.
Th e extraction system functions with negative pressure (va-
cuum) that draws the air through suction casings/nozzles,
hose system, separator and fi lter system. Coarse separation
of dust occurs in the units cyclone which is a highly effi cient
separator for larger particulate. Th e fi ne dust is separated
and contained by the units fi lter system. Separated material
is collected for disposal in the plastic sack or container at
the base of the cyclone.
Operation
Connect the machine to compressed air.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running.
Reverse pulse fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
Th e vacuum is generated in an ejector which means:
-
maintenance free vacuum producer
-
low weight
-
no electrical connection required in hazardous
environments
-
extremely reliable
Th e fi lter is cleaned with reverse pulse giving the fi lter extra
long life and retaining maximum capacity.
level is about 5 cm under the foot valve. Th e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks.
Note! Low main pressure and damages in the compres-
sed-air line will result in poor performance.
DC 5800TR - 9
Part No 9458