Dc Voltage Measurement; Measuring Ac Current - Metrix MX 650 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
Chapter II

4.2. DC voltage measurement

• (MX 650) Set the switch
• (MX 655) Set the switch
Press on the
display the
600
1000
PEAK
(direct signal).
1mS
HOLD
A
1000
V
400
Connect the red test lead to
40
Hz
the "+" input terminal and
REL
the black test lead to the
"COM" input terminal.
600
750
1000
600V
Then place the touch prods
in contact with the points
where the DC voltage is to
be measured.
Then read the result on the
display.

4.3. Measuring AC current

• (MX 650) Set the switch to
A (corresponding to the 1000
A~ and 400 A~ automatic calibres).
• (MX 655) Set the switch to 1000 A
(alternating signal) should be displayed. If not, press on the
/
button, to make it appear.
Open the clamp jaws by pressing the trigger. Position the
clamp around the conductor to be measured.
Release the trigger. Check the clamp is properly closed.
Read the result of the measurement on the display.
If reading is difficult, press the HOLD button and read the
result afterwards.
If necessary, for better resolution you can move to a lower
range by means of the selector switch.
Note: For safety reasons, disconnect the measuring leads
before measuring current. The clamp should encircle only one
conductor, otherwise the measurement result may be
incorrect. The best measurement is obtained with the
conductor centred in the middle of the jaws.
MX 650 / MX 655
to
V.
to
V.
/
button to
symbol
. The
symbol
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mx 655

Table des Matières