TROUBLESHOOTING
Machine Actions
The machine does not switch on.
The machine requires a lot of time to
heat up.
The pump is noisy
The lever cannot reach the dispensing
position.
The coff ee is cold.
The coffee is brewed too fast or the
brewed coff ee is not creamy.
Coff ee is not brewed or brewed in drips
only.
Hot water or steam not dispensed
(GXI/02)
The milk does not froth.
Please contact customer service for any problems not covered in the above table or when the suggested solutions do not solve the problem.
TECHNICAL SPECIFICATIONS
The manufacturer reserves the right to make changes to the technical specifi cations of the product.
Nominal Voltage - Power Rating - Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See label on the inside of the service door
Housing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermoplastic material
Size (width x depth x height) (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 x 332 x 273
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 kg
Power Cord Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 m
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On the upper part
Water Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 litres – Removable
Used capsule drawer capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Pump pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ÷ 19 bar
Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless steel
Safety mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermal fuse
R
C
US
• 21 •
Causes
The machine is not connected to the electric
network.
The appliance is full of limescale.
No water in the tank.
The tank has been filled without priming the
water circuit.
Used capsule drawer full.
The capsule is not inserted correctly.
"
"
(GXI/01) - The
button was blinking
when pressed.
No coffee without capsule (as suggested) has
been brewed.
Used capsule.
"
"
(GXI/02) - The
button was blinking
when pressed.
No water in the tank.
The water circuit is empty.
Clogged steam wand.
The hot water/steam knob is open incorrectly.
Not suitable milk.
The milk is too hot.
Type Sin 030H - Sin 030HRD
Solutions
Connect the machine to the electric network.
Contact the authorized service centre.
Descale the machine.
Refi ll with fresh drinking water.
Prime the water circuit (see section "Priming the water cir-
cuit").
Empty the used capsules drawer. Insert the capsule by repeat-
ing the whole sequence. If this should not prove successful, dis-
connect the machine from the electric network and intervene
manually to remove the capsule from the compartment
Insert the capsule again.
"
"
Wait until the
button turns on and remain fi xed.
Brew a coff ee without capsule and then brew another one with
a capsule.
Insert a new capsule and repeat the steps.
"
"
Wait until the
button turns on and remain fi xed.
Refi ll with fresh drinking water.
Prime the circuit (section "Using the Machine for the First
Time").
Clean the spout with a needle.
(The machine should be turned off and cold, and the
hot water / steam knob should be closed).
Turn the hot water / steam knob to its limit stop.
Use fresh, partially skimmed milk.
Use milk at fridge temperature.