Installation instructions
The installation comes under the exclusive res-
ponsibility of specialists.
The installer is held to respect the legislation
and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infil-
tration of liquids in the cabinet.
His installation has to be done carefully, in con-
formity of the following drawing.
Fitting - installing:
• The cut out sizes are:
Reference
Cut-size
BIKP-90
810 x 490 mm
• Ensure that there is a distance of 50 mm
between the hob and the wall or sides.
• The hobs are classified as "Y" class for heat
protection. Ideally the hob should be instal-
led with plenty of space on either side. There
may be a wall at the rear and tall units or a
wall at one side. On the other side, however,
no unit or divider must stand higher than the
hob.
• The piece of furniture or the support in which
the hob is to be fitted, as well as the edges
of furniture, the laminate coatings and the
glue used to fix them, must be able to resist
temperatures of up to 100 °C.
• The mural rods of edge must be heat-resi-
sting.
• Not to install the hob to the top of a not ven-
tilated oven or a dishwasher.
• To guarantee under the bottom of the hob
casing a space of 20 mm to ensure a good
air circulation of the electronic device.
2 mm
Stick the gasket (2) two millimeters from the
external edge of the glass, after removing the
protection sheet (3).
• If a drawer is placed under the work, avoid to
put into this drawer flammable objects
(for example: sprays) or not heat-resistant
objects.
• Materials which are often used to make
worktops expand on contact with water. To
protect the cut out edge, apply a coat of
varnish or special sealant. Particular care
must be given to applying the adhesive joint
supplied with the hob to prevent any leakage
into the supporting furniture. This gasket
guaranties a correct seal when used in con-
junction with smooth work top surfaces.
• The safety gap between the hob and the coo-
ker hood placed above must respect the indi-
cations of the hood manufacturer. In case of
absence of instructions respect a distance
minimum of 760 mm.
• The connection cord should be subjected, af-
ter building, with no mechanical constraint,
such for example of the fact of the drawer.
D
EN
35