CHECKS AT THE START OF THE SEASON
Ma e sure the power cable and soc et are in perfect condition
and ma e sure the earthing system is e cient. Comply strictly
with the installation standards.
END OF SEASON OPERATIONS
To drain all water from the circuit, remove the cap A11 from the
drainage on the bac of the appliance and allow the water to
drain out into a basin (fig. 10).
To facilitate this operation, at the start of the season, it's possible
to apply the water drain hose with cap B6.
In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season
dust cover B8 and you put the accessories in the relevant
end of season accessories bag B9.
10
When the appliance is empty, replace the cap.
Clean the filter and dry thoroughly before putting bac .
TECHNICAL SPECIFICATIONS
Power supply voltage see rating label
Max. absorbed power during air conditioning
Refrigerant
Cooling capacity
LIMIT CONDITIONS
Room temperature for
air conditioning
Room temperature for
heating
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will brea down from lac of oil.
ELECTRICAL CONNECTION
This appliance is equipped with a 3 prong grounded plug. The
plug must be connected into an outlet that is properly installed
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance.
If it will not fit the outlet, have a proper outlet installed by a
qualified electrician or relocate the unit to a proper outlet. If the
household electrical supply does not meet the above specifica-
tions, or if you are not sure your home has an effective electrical
ground, have a qualified electrician or your local electrical utility
company chec it and correct any problems.
SAFETY PLUG
The appliance is fitted with a safety plug to protect the power
cable. If power is cut off, unplug from the outlet and ma e sure
the power cable is undamaged. If the cable is damaged, call the
service center immediately. If power cuts off frequently and the
power cable is undamaged, contact a qualified electrician.
OPERATION OF THE SAFETY PLUG
"
If the safety device incorporated in the plug trips and cuts off
"
the power supply, chec that the power cable and plug are not
"
damaged. If the power cable is undamaged, to restore operation
press the "RESET" button. To verify correct operation of the plug,
press the " TEST" button periodically and ma e sure the appliance
disconnects. If this is not the case, contact the service center. To
restore operation, press the " RESET" button.
64 ÷ 95°F (18° ÷ 35°C)
50 ÷ 77°F (10 ÷ 25°C)
14