Cleaning The Cabinet; Technical Specifications - DeLonghi EL Série Mode D'emploi

Masquer les pouces Voir aussi pour EL Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

do not cover the appliance
Never rest objects of any kind on the air conditioner;
Never obstruct the air intake or outlet grilles;
CLEANING
Before cleaning or maintenance, turn the appliance off by using
the
button, then unplug from the outlet.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then
dry with a dry cloth. For safety reasons, never wash the air con-
ditioner with water.
Precautions
Never use petrol, alcohol or solvents to clean the appliance. Nev-
er spray insecticide liquids or similar.
CLEANING THE BIO SILVER AIR FILTER (If fitted)
If the filter is dirty, air circulation is compromised and the ef-
ficiency of the dehumidifying and air purifying functions de-
creases. It is therefore good practice to clean the filter at regular
intervals. The frequency depends on the duration and conditions
of operation. If the unit is used constantly or systematically, you
are recommended to clean the filter once a week.
The filter is housed in the intake grille.
Remove the grille to access the filter. To clean the filter, it will
need to be extracted as shown in fig. 9.
9
Use a vacuum cleaner to remove any dust deposited on the filter.
If it is very dirty, submerge it into warm water and rinse it several
times. The water temperature must be kept below 104° F (40°C).
After washing the filter, allow it to dry completely before reposi-
tioning it. The BioSilver filter helps capture dust and pollen and
helps reduce the growth of bacteria and mold on the filter.
CHECKS AT THE START OF THE SEASON
Make sure the power cable and socket are in perfect condition
and make sure the grounding system is sufficient. Comply strict-
ly with the installation standards.
END OF SEASON OPERATIONS
To drain all water from the circuit, remove the cap A11 from the
drainage on the back of the appliance and allow the water to
drain out into a basin (fig. 10). To facilitate this operation, at the
start of the season, it's possible to apply the water drain hose
with cap B6.
In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season
dust cover B8 and you put the accessories in the relevant
end of season accessories bag B9.
10
When the appliance is empty, replace the cap.
Clean the filter and dry thoroughly before putting back. Unit
should be stored in large, well ventilated area.

TECHNICAL SPECIFICATIONS

Power supply voltage
Max. absorbed power during air conditioning
Refrigerant
Cooling capacity
LIMIT CONDITIONS
Room temperature for
air conditioning
Room temperature for
heating (on some models only)
Maximum relative humidity :
Transport, filling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
15
see rating label
"
"
"
64 - 95°F (18° - 35°C)
50 - 77°F (10 - 25°C)
80% RH

Publicité

Table des Matières
loading

Table des Matières