TO CLEAN (BACKWASH) THE FILTER
When the pressure has increased by 0.5 bar or more (the measurement registered above) the
filter sand needs to be backwashed. This is done as follows:
1. Shut off the pump.
2. Shift the valve handle to "Filter backwash".
3. Start pump and let it run until water is clean
(Sidemount: about 5-10 minutes; Topmount: about 3 minutes).
4. Shut off the pump and turn off the water supply to the pump.
5. Clean the basket of the pump and turn on the water supply to the pump after closing the
cleaning strainer dome.
6. Shift valve handle to "Rinse" position.
7. Start pump and run for approximately one minute.
8. Shut off the pump.
9. Shift valve handle to position "filtration" and start the pump.

SERVICING AND MAINTENANCE

Proper care and maintenance will add many years of service and enjoyment to the pool. To
clean filter exterior of dust, dirt, wash with a mild detergent and water, then hose off. Never
wash the transparent dome with a solvent as it may become cloudy.
REPLACEMENT OF SAND
Open the drain and let the water flow out. Remove the sand. This can be done by means of
the vacuum system "Sandvak", which can be connected to the main water supply just like a
garden hose. The filter can also be emptied by hand.
Sidemount: To replace the sand, turn the top diffuser system to the side. The thread of the
filter should be protected, in the same way as with filling.
TAKE CARE NOT TO DAMAGE THE BOTTOM LATERALS. THE SAND IN THE FILTER MUST
BE CHANGED EVERY 5 YEARS. DO NOT CLEAN OR SPRAY THE DOME WITH LUBRICANT
!
THAT CONTAIN ALCOHOL.
WINTERIZING
In areas that have freezing winter temperatures protect pool equipment. The filter, pump and
pipelines must be emptied to protect them from freezing. To do this move the valve handle
to the "Backwash" position, open drain tap with hose connection end 180° to the left (do not
unscrew) and open the bleed valve. Open all valves. A small flexible piece of tubing can be
attached to the drain tap. Allow filter, pump and pipelines to drain completely.