ECL-76, ECL-102, ECL-103
7
Connection
A
NOTICE!
Make sure that you run the on/off cable away from live power cables.
!
WARNING!
To prevent short circuits, always disconnect the negative terminal of the
vehicle battery before working on the vehicle electrical system.
If the vehicle has an additional battery, its negative terminal must also
be disconnected.
The cable cross section for the connection between the starter battery,
power relay and consumer battery must not be less than 16 mm² for the
ECL-76 and 35 mm² for the ECL-102/ECL-103. Also check that the cable
between the negative terminal of the consumer battery and vehicle chassis
is at least 16 mm² and 25 mm² respectively – you might need to replace the
cable provided with a thicker one. The minimum cable cross sections are
listed in the following table.
I
NOTE
You can use the following cable set for the SinePower inverters:
SinePower MSI1812T/MSI1824T: 9102700002
SinePower MSI2312T/MSI2324T: 9102700004
The table shows the combinations possible of roof air conditioners, under-bench air con-
ditioners, charging current distributors and inverters and the necessary cable cross sec-
tions of the access leads:
Air conditioner
Dometic CA1000
Dometic CA1000
Dometic CA1000
Dometic CA2500
Dometic CA2500
Dometic CA2500
Dometic B1600
Dometic B1600
Dometic B1600
Dometic
B1600 Plus
EN
Charging current
distributor
ECL-76
ECL-102
ECL-103
ECL-102
ECL-102
ECL-103
ECL-102
ECL-102
ECL-103
ECL-102
Inverter
PerfectPower PP1002
SinePower MSI1812T
SinePower MSI1824T
PerfectPower PP2002
SinePower MSI1812T
SinePower MSI1824T
PerfectPower PP2002
SinePower MSI1812T
SinePower MSI1824T
PerfectPower PP2002
Connection
Cable cross
section
16 mm
minimum
2
35 mm
minimum
2
35 mm
minimum
2
25 mm
minimum
2
35 mm
minimum
2
35 mm
minimum
2
25 mm
minimum
2
35 mm
minimum
2
35 mm
minimum
2
25 mm
minimum
2