Connection
7.4
DC-Kit2 with Dometic B1600/Systems with enable input
Roof air conditioner:
– Dometic B1600
– Systems with enable input approved by the manufacturer
Circuit diagram: fig. 4, page 6
Charging current distributor: ECL-102
Inverter: PerfectPower PP2002
➤ Install the switch, which is connected to the two-wire cable, in an easily-accessible
place.
➤ Connect the system plug to the inverter. Divide a wire of the cable in such a way that
the ends produced can be connected to the I2/l3 connectors of the ECL-102 with wire
sleeves. If necessary, extend the wires with a suitable cable.
7.5
DC-Kit2 with Dometic FreshJet1100/1700/2200,
FreshLight1600/2200
Roof air conditioner:
– Dometic FreshJet1100/1700/2200
– Dometic FreshLight1600/2200
Circuit diagram:
– Dometic FreshJet1100/1700/2200: fig. 6, page 8
– Dometic FreshLight1600/2200: fig. 7, page 9
Charging current distributor: ECL-102
Inverter:
– Dometic FreshJet1100/1700/2200: SinePower MSI1812T
– Dometic FreshLight1600/2200: PerfectPower PP2002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
➤ Remove the FreshJet/FreshLight's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the FreshJet1100/1700/2200, FreshLight1600/2200 to the plug
connector on the circuit board (fig. p, page 27 for FreshJet and fig. q, page 27 for
FreshLight).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (item no. 4441300124) to the
two wires on the on/off cable of the FreshJet1100/1700/2200, FreshLight1600/2200.