ECL-76, ECL-102, ECL-103
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the FreshJet1100/1700/2200 or FreshLight1600/2200 to the
plug connector on the circuit board (fig. p, page 27 for FreshJet and fig. q, page 27
for FreshLight).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (item no. 4441300124) to the
two wires on the on/off cable of the FreshJet1100/1700/2200 or FreshLight1600/2200.
7.9

DC-Kit4/DC-Kit6 with Dometic B2600

 Roof air conditioner: B2600
 Circuit diagram: fig. h, page 20 (12 V), fig. k, page 23 (24 V)
 Charging current distributor: ECL-102/ECL-103
 Inverter: SinePower MSI2312T/MSI2324T
➤ Install inverter remote control MCR-9 in an easily-accessible place (jumper closed,
refer to remote control installation manual) and connect its cable to the inverter.
➤ Remove the B2600's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the B2600 (item no. 4441300129) to the plug connector on the
circuit board (fig. r, page 28).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2600.