Connection
7.10
DC-Kit4/DC-Kit6 with Dometic B3200
Roof air conditioner: Dometic B3200
Circuit diagram: fig. i, page 21 (12 V), fig. l, page 24 (24 V)
Charging current distributor: ECL-102/ECL-103
Inverter: SinePower MSI2312T/MSI2324T
➤ Install inverter remote control MCR-9 in an easily-accessible place (jumper closed,
refer to remote control installation manual) and connect its cable to the inverter.
➤ Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
➤ Use the blue wire of the universal connection cable (item no. 4441300124) to join the
I5 connection of the ECL-102/ECL-103 to the MCR-9 remote control (use wire
sleeves).
➤ Use the brown wire of the universal connection cable to join the D+ input to the
I2 connection on the ECL-102/ECL-103 (use wire sleeves).
7.11
DC-Kit4/DC-Kit6 with Dometic
FreshJet1100/1700/2200/2600/3200
Roof air conditioner: Dometic FreshJet1100/1700/2200/2600/3200
Circuit diagram: Dometic FreshJet1100/1700/2200/2600/3200:
fig. j, page 22 (12 V), fig. m, page 25 (24 V)
Charging current distributor: ECL-102/ECL-103
Inverter: SinePower MSI1812T/MSI1824T
➤ Install inverter remote control MCR-9 in an easily-accessible place and connect its
cable to the inverter.
➤ Remove the FreshJet1100/1700/2200/2600/3200 outlet panel, if necessary remove
the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the FreshJet1100/1700/2200/2600/3200 to the plug connector
on the circuit board (fig. p, page 27 for FreshJet).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (item no. 4441300124) to the
two wires on the on/off cable of the FreshJet1100/1700/2200/2600/3200.
104
ECL-76, ECL-102, ECL-103
EN