Sundstrom SR 580 Notice D'utilisation page 23

Masquer les pouces Voir aussi pour SR 580:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
2. Parts
2.1 Delivery check
Check that the equipment is complete in accordance with the
packing list, and undamaged.
Packing list
• Helmet
• Breathing hose
• User instructions
• Cleaning tissue
2.2 Accessories / Spare parts
Designation
Helmet, incl. air duct
Upper frame set
Lower frame set
Head harness
Face seal
Leaf spring
Set of valves
Visor, PC
Sweatband
Breathing hose for SR 580
O-ring fo r hose, fig. 1c/2c
Gasket SR 200/SR 580, fig 1a/2a
Peel of set SR 582 *
Cleaning wipes. 50/box
* Must not be used in potentially explosive atmosphere
3. Use
3.1 Installation
Also see the user manual for the SR 500/SR 500 EX/SR 700 fan
and the SR 507 compressed air attachment, whichever is used.
Breathing hose
One end of the hose has a ø42 mm thread (fig. 1b/2b), whilst
the other is fitted with an O-ring (fig. 1c/2c). The threaded end
is to be connected to the helmet.
3.2 Donning
Also see the user instructions for the SR  500/SR  500 EX/
SR  700 fan and the SR  507 compressed air attachment,
whichever is used.
• Check that the 6-point harness is secured correctly (fig. 9).
• Raise the visor and put on the helmet (fig. 10).
• If necessary, adjust the width of the helmet using the knob
located at the rear of the harness (fig. 11).
• To adjust the height of the helmet interior, move the pins
between positions a and b (fig. 12). If the interior is attached
to pin a, the helmet will sit lower, and on pin b the helmet
will be higher. To achieve the best fit, this adjustment can
be made at both the front and back of the helmet.
• Lower the visor by pulling the face seal down below your
chin. A 'click' indicates that the visor is fully lowered (fig. 13).
• Insert a finger inside the face seal and move it along the
length of the contact surface to check the fit (fig. 14).
• Make sure that the breathing hose runs down your back
and is not twisted. You can adjust the angle of the helmet
connection as required (fig. 15).
Hearing protectors
It is possible to attach hearing protectors into the slot connec-
tion on the sides of the face shield. Fig 18.
If necessary, adjust the head harness of the face shield to get
the hearing protectors in correct position, see 3.2 Donning.
3.3 Doffing
See the user manual for the SR 500 /SR 500 EX/SR 700 fan
and the SR  507 compressed air attachment, whichever is
going to be used.
4. Maintenance
The person responsible for cleaning and maintaining the
equipment must have suitable training and be well acquainted
with work of this type.
4.1 Cleaning
Sundström cleaning tissues SR 5226 are recommended for
daily care.
If the equipment is more heavily fouled, use a soft brush or
Order no.
sponge moistened with a solution of water and dishwashing
R06-0801
detergent or the like. Rinse the equipment and leave it to dry.
R06-0802
If necessary, spray the helmet with 70 % ethanol or isopropanol
R06-0803
solution for disinfection.
R06-0804
NOTE! Never use a solvent for cleaning.
R06-0805
4.2 Storage
R06-0806
After cleaning, store the equipment, dry and clean, at room
R06-0807
temperature. The SR 580 should be stored with the visor either
R06-0808
fully raised or fully lowered. Keep out of direct sunlight.
R06-0809
4.3 Maintenance schedule
R06-0810
R06-0202
Recommended minimum requirements on maintenance
routines so you will be certain that the equipment will always
R01-1205
be in usable condition.
T06-0801
H09-0401
Visual inspection
Performance check
Cleaning
Replacement of hose O-ring
Replacement of gasket
in helmet
Replacement of
exhalation membrane
At the first signs of wear, impact marks, damage or aging of the
material, the helmet shell or harness must be replaced in order
to ensure the protective ability of the helmet is maintained. This
must be checked on a regular basis.
A helmet that shows signs of damage, e.g. cracks or scratches,
that may reduce its protective ability must be discarded. The
helmet must also be discarded if it has been exposed to
stresses during an accident or near accident, even if there is
no visible damage.
The helmet should be used within 5 years after the date of
production or within 3 years of being taken into use, whichever
of these dates is the earlier.
4.4 Change parts
Always use Sundström genuine parts. Do not modify the
equipment.
Use of non-genuine parts or modifications may reduce pro-
tective function and put at risk the approvals received by the
product.
4.4.1 To change the exhalation membrane
The exhalation membrane is fitted on a pin inside the valve
cover. The cover must be replaced at the same time as the
membrane. Do the following:
• Remove the valve cover from the valve seat (fig. 16).
• Pull out the membrane.
Before use
After use Annually
23

Publicité

Table des Matières
loading

Table des Matières