ABIPLAS
WELD CT
2.5 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
• Coolant supply
• Gas supply
Further measures can be found in the power source operating instructions or the documents for
further peripheral devices.
3 Product description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
• Only qualified personnel are permitted to perform work on the device or system.
NOTICE
• The torch body, cable assembly and complete bracket together form an entity.
6.4 Attaching the torch body to the complete bracket on page EN-14
3.1 Technical data
Welding
Transport and storage
Relative humidity
Tab. 1
Ambient conditions during operation
®
Type ABIPLAS
WELD
Type of use
DC polarity of the electrodes
Voltage rating
Max. arc inflammability and stabilisation
voltage
Breakdown voltage 50 Hz
Protection type of the device connections
(EN 60529)
Tab. 2
Product-specific torch data (EN 60974-7)
BAL.0128 • 2019-09-04
−10 °C to +40 °C
−25 °C to +55 °C
Up to 90 % at 20 °C
150 CT20
Automatic
Usually positive
Peak value of 141 V
4.5 kV
3 Product description
250 CT20
IP2X
EN - 5