82
2. Insert the reader into the blind module FLUSH WITH THE TOP (Fig. 19/1).
Fig. 19: Insert the WRU 220 reader into the blind module
3. Reinsert the clamping plate into the blind module and fix it (Fig. 20).
Fig. 20: Insert the mounting plate and fix it
4. Connect the connection leads to the clips of the reader (Fig. 39/p. 100).
5. Insert the cables into the housing and clip the blind cover with the reader onto the
frame.
NOTE
Risk of damage to the leads!
• Carefully push the reader and leads into the switch box.
• Ensure that the leads are not trapped.
1
1