SinePower
Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches.
In this way, the battery you connect to the inverter is not discharged as quick-
ly.
The inverter operates in energy-saving mode as long as the required power
is below the set level. If the required power exceeds the set level, the inverter
works in normal mode.
The values to be set on your inverter can be found in the following table:
Energy-saving mode
MSI900
Off
70 – 110 W
180 – 240 W
Defining settings
Using the S8 dip switch you can define whether the default settings or the
settings of dip switches S1 – S7 are used.
Parameter
Default settings
Use dip switch S1 – S7
Default settings
Mains voltage
230 V
EN
MSI1300
MSI1800
Off
60 – 120 W
110 – 190 W
130 – 170 W
190 – 240 W
180 – 240 W
240 – 300 W
Net frequency
S4
Off
Off
On
On
On
Dip switch
S8
On
Off
Energy-saving mode
50 Hz
Using the inverter
Dip switch
S5
S6
Off
Off
Off
Off
On
Off
On
On
Off
55