INSTALLATION

General

Hatco Split Drawer Warmers are shipped with most
components pre-assembled. Care should be taken when
unpacking the shipping carton to avoid damage to the unit and
components enclosed.
WARNING
ELECTRIC SHOCK HAzARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAzARD: Locate unit a minimum of 1" (25 mm) from
combustible walls and materials. If safe distances are not
maintained, combustion or discoloration could occur.
NOTICE
Do not lay unit on the front or back side. Damage to the
unit could occur.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION section for
details.
2. Remove tape and protective packaging from all surfaces of
unit.
3. Install the 4" (102 mm) legs.
a. Remove the plastic bag containing the four legs from
the top drawer of the unit.
b. Carefully lay the unit on its side (requires two people).
c. Thread a leg into the hole located at one corner of the
unit.
d. Hand-tighten the leg until snug. Do not over-tighten.
e. Repeat steps c and d for the remaining three legs.
f. Return the unit to its upright position (requires two
people). If the unit is not level or rocks, turn the
adjustable tip of the appropriate leg to level the unit.
4. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
avoid areas that may be subject to active air movements
or currents (i.e., near exhaust fans/hoods, air
conditioning ducts, and exterior doors).
• make sure the unit is located on solid, level flooring.
• make sure the unit is at the proper height in an area
convenient for use.