Compaq Smart Array 5i Plus Manuel De L'utilisateur page 133

Table des Matières

Publicité

Tableau F-1: Messages d'erreur POST
Code
1794
1795
1796
1797
Contrôleur Smart Array 5i Plus et module d'activation de cache avec batterie Compaq
Message
Slot x drive array –
array accelerator
battery charge low.
Array accelerator is
temporarily disabled.
Array accelerator will
be re-enabled when
battery reaches 90%
charge.
If the battery pack has
failed, this message
will also be displayed:
Array accelerator
batteries have failed to
charge and should be
replaced (Compaq
spares #120978-001)
Slot x drive array –
array accelerator
configuration error.
Data does not
correspond to this
drive array. Array
accelerator is
temporarily disabled.
Slot x drive array –
array accelerator is not
responding. Array
accelerator is
temporarily disabled.
Slot x drive array –
array accelerator read
error occurred. Data in
array accelerator has
been lost. Array
accelerator is disabled.
...suite
Signification et action recommandée
La batterie est chargée à moins de 90%. Les
mémoires à écriture différée sont désactivées.
Lorsque les batteries seront à pleine charge,
l'accélérateur RAID sera réactivé
automatiquement et ce message POST
disparaîtra. Remplacez l'accélérateur RAID ou le
contrôleur RAID si les batteries ne se rechargent
pas sous 36 heures.
Si le module batterie est en panne, remplacez-le.
Les données stockées dans l'accélérateur RAID
ne correspondent pas à cet accélérateur RAID.
Faites correspondre l'accélérateur RAID au
module RAID correspondant.
-ou-
Exécutez l'utilitaire de configuration de système
Compaq pour effacer les données de
l'accélérateur RAID.
Remplacez l'accélérateur RAID ou le contrôleur
RAID Smart.
Remplacez l'accélérateur RAID ou le contrôleur
RAID Smart. Restaurez les données à partir de la
sauvegarde.
Messages d'erreur POST
...à suivre
F-15