Messages d'erreur POST
Tableau F-1: Messages d'erreur POST
Code
1729
1753
1754
1755
1756
F-4
Contrôleur Smart Array 5i Plus et module d'activation de cache avec batterie Compaq
Message
Slot 1 drive array –
disk performance
optimization scan in
progress – RAID 4/5
performance may be
higher after completion
Slot x drive array –
array controller
maximum operating
temperature exceeded
during previous
power up.
Slot z drive array –
RAID ADG drive(s)
configured but ADG
Enabler Module is
detached or defective.
Please check for
detached ADG
Enabler Module. Array
accelerator is
temporarily disabled.
Slot z drive array –
ADG Enabler Module
appears to be
defective. Please
replace the ADG
Enabler Module.
Slot x redundant
controllers are not the
same model.
...suite
Signification et action recommandée
Ce message suit normalement la configuration
initiale des unités logiques RAID 4 ou RAID 5. Ce
message d'erreur POST disparaîtra et les
performances du contrôleur s'amélioreront dès
que les données de parité auront été initialisées
par ARM (processus automatique qui s'exécute en
arrière-plan sur le contrôleur).
Ce message apparaît à la mise sous tension
suivante si le contrôleur se bloque pour une raison
de température excessive. Vérifiez que le
ventilateur du serveur fonctionne correctement.
Un module d'activation ADG doit être branché lors
de la configuration de volumes RAID ADG, sinon
l'accélérateur RAID sera désactivé. Repositionnez
le module d'activation ADG.
Remplacez le module d'activation ADG défectueux
ou retirez-le s'il n'est pas nécessaire (c'est-à-dire
si aucune unité logique RAID ADG n'est
configurée).
Les contrôleurs redondants ne sont pas du même
modèle. Utilisez deux contrôleurs identiques pour
la redondance.