Troubleshooting
If the machine does not function properly, please check the below table for the solution. If you are still un-
able to solve the problem, please contact the supplier/service provider.
Problems
The machine does not switch on.
The vacuum bag is not vacuum and / or
sealed completely.
Vacuum bag loses vacuum after being
sealed.
Error codes display
Error codes shown on the digital display
(F)
E01
LP
Technical specification
Item no.
Operating voltage and frequency
Rated input power
Protection class
Max vacuum bag width
Pump capacity
Pressure
Width of sealing bar
Dimension
Net weight
Remark: Technical specification is subjected to change without prior notification.
Possible cause
Power plug is not connected properly with
the electrical power outlet.
Vacuum/ Seal time is not long enough.
The opening of the vacuum bag was not
entirely and properly placed under the
sealing bar (8).
The sealing bar (8) and the inside vacuum
chamber (9) is not clean enough.
There is some moisture, food particles or
debris on the seal area of the vacuum bag.
Inside the vacuum bag has food with
sharp points to penetrate the bag and
thus air enters into the vacuum bag.
Some food can release gases also food
can release gases due to food spoilage.
Possible cause
- The lid (1) is not properly closed.
- Oil pump is defective.
- Machine internal system is defective.
- Machine lost electrical power supply
suddenly during operation.
-29,9" Hg / -1012 mbar (± 3%) directly at the pump
-29,8" Hg / -1009 mbar (± 3%) in vacuum chamber
Possible solution
Make sure the power plug is connected
properly with the electrical power outlet.
Set longer Vacuum/Seal time.
Pack the food in a new bag and place
properly in the chamber so the entire
opening can be sealed. Don't use bags
that don't fit the sealing bar.
Wipe the surface of the sealing bar (8)
and inside the vacuum chamber (10) to
keep clean, dry and free of debris.
Wipe the seal area of the vacuum bag to
make sure it is dry and clean.
Cut off the sharp points or cover it before
packing.
Blanch or frozen the food properly before
packaging. Discard the food if in doubt.
Possible solution
- The lid (1) is not properly closed.
- Contact the supplier.
- Contact the supplier.
- Check the electrical power supply.
201442
220-240V~ 50 / 60 Hz
1100W
Class I
410 mm
333,3 L/min
2 x 3,5 mm
505 x 567 x (H) 465 mm
approx. 60kg
EN
9