CAUTION: Check that all the cover pan-
els are in the correct position and are locked via
fixing screws before commissioning.
CAUTION: Always disconnect the power
supply if the appliance is not used for a long pe-
riod of time.
►►4.2. CONTROL PANEL
(FIG. 5)
The units are equipped with a luminous signalling
panel that indicates their operating status.
A brief description of their meaning is provided be-
low.

CONTROL PANEL:

►[ - - ] (SHOWN ON THE DISPLAY): The display
shows [ - - ] when the unit is connected to the
mains and electrically powered.
LED:
►FAN SPEED LED: These LEDs indicate the set
ventilation speed (LOW > Low Speed / HIGH >
High Speed).
►ALARM LED: This LED is on when the unit is in
alarm. The display will show the error message.
►WORKING LED: This LED is on when the com-
pressor is running. The LED flashes when the
dehumidifier is waiting to restart or is in defrost
mode. The LED turns off when the desired
amount of humidity has been reached in the
"ON" status.
►FULL LED: This LED is on when the conden-
sate tank is full or if the pump is in alarm.
BUTTONS:
►ON/OFF: To turn on the dehumidifier, simply
press the "ON/OFF" button. Based on the rela-
tive humidity set, the appliance starts working.
When the room humidity reaches the required
level, the appliance goes into stand-by mode
and the unit stops, but remains in the "ON" sta-
tus (POWER LED on). If the room humidity rises
again, exceeding the previous set point, the de-
humidifier restarts again.
Press the "ON/OFF" button to turn off the appli-
ance (with the appliance off, the display shows
[ - - ]).
►FAN SPEED: Press the "FAN SPEED" button
to select the desired ventilation speed (LOW >
Low Speed / HIGH > High Speed).
►"-" / "+" (HUMIDITY SET): Press the "-" / "+" but-
tons to set the relative humidity desired. The
display will start flashing, showing the new refer-
ence set point. After a few seconds the display
stops flashing and the new humidity set point
has been detected by the electronics.
It is possible to operate the appliance regard-
less of the degree of humidity present in the en-
vironment. By pressing the "-" button until the
"CONT" message appears on the display, the
appliance will operate continuously.
►HOURS: Press the "HOURS" button to view the
working hours of the appliance.
►►4.3. DISCHARGE PIPE CONNECTION
(Set-up)
(FIG. 6)
A discharge pipe can be connected to the appli-
ance. A hose connection with a diameter of 16
mm is fitted on the tank.
►►4.4. CONNECTION OF THE CONDEN-
SATE PUMP (Optional)
(FIG. 7)
Depending on the model, the appliance can
be set up for the connection of the condensate
discharge pump.
For a correct connection, disconnect the unit from
the power supply before carrying out any opera-
tion.
For a correct installation of the condensate pump,
refer to the technical manual included in the op-
tional kit.
►►4.5. STORAGE
(FIG. 8)
The dehumidifier has been designed with specific
shapes of the upper part of the cover which allow
you to place a second dehumidifier on top. Make
sure to perform the stacking operation in complete
safety.
CAUTION: Do not stack more than one dehumi-
difier.