Preliminary Operations; Preliminary Checks - Master DHP 65 Manuel D'utilisation Et De Maintenance

Masquer les pouces Voir aussi pour DHP 65:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
en
Flammable material hazard.
it
This unit is hermetically sealed and contains fluor-
inated gas R1234yf GWP (R1234yf) = 4.
de
es
fr
►►►3. PRELIMINARY OPERATIONS
nl
pt
►►3.1. REMOVAL OF THE PACKAGING
da
AND ASSEMBLY
Remove the packaging taking care not to dam-
fi
age the unit. Dispose of the packaging products
(wood, plastic, cardboard), taking them to the spe-
no
cialised collection or recycling centres (follow the
sv
local regulations in force).
CAUTION: Depending on the model, assem-
pl
ble the appliance, with any handles, wheels and
ru
all relevant hardware (FIG. 3) housed inside the
packaging before commissioning.
cs
hu
►►3.2. INSPECTION
sl
All units are factory assembled and wired (ex-
cept for certain components). Upon receiving the
tr
unit, it must be immediately and thoroughly in-
hr
spected, checking that it has not been damaged
during transport or that no parts are missing.
lt
lv
Before use, specifically check for any dents
on the external panels, including those in the tank
et
compartment. Also check that the cable, plug and
relevant insulation are intact. Otherwise, it is FOR-
ro
BIDDEN to connect and start the unit, which must
be sent to an authorised service centre.
sk
bg
►►3.3. OPERATING PRINCIPLES
uk
CAUTION: To ensure correct operation of
bs
the appliance, it is recommended to operate
the unit within the limits shown on the techni-
el
cal data table.
zh
►►3.4. POSITIONING
Place the appliance to ensure an adequate air
flow.
CAUTION: Make sure that the appliance is
placed in such a way so as to prevent contact with
water.
►►3.5. SERVICE AREA
The hot air expelled by the fan must not be ob-
structed. Avoid hot air recirculation between suc-
tion and delivery to prevent compromising the per-
formance of the unit or even interrupting normal
operation.
CAUTION: The equipment must not be placed
in cramped environments, which do not allow ade-
quate distribution of the air from the air outlet grille
into the room.
CAUTION: Do not place or hang objects on
the front panel, it may cause damage to the unit.
►►3.6. GENERAL INFORMATION
CAUTION: Disconnect the power plug from
the socket before carrying out any maintenance
operation on the electrical part.
CAUTION: Check that the supply voltage cor-
responds to the unit's operating data (voltage and
frequency) shown on the data plate on the dehu-
midifier. The appliance is fitted with a power cable
for correct operation.
CAUTION: The earthing connection is manda-
tory.
►►►4. START-UP
►►4.1. PRELIMINARY CHECKS
IMPORTANT: In dual voltage models
(...DV), check:
►1-POSITION OF THE VOLTAGE CHANGE
SWITCH (220-240V / 110-120V) (FIG. 4): If
the set voltage does not match that supplied
by the mains, the voltage must be adapted.
Loosen the two lid screw fasteners, shift/
press the switch onto the voltage value sup-
plied and mount the lid again.
►2-CHECK THE TYPE OF SOCKET: If the type
of socket does not match the power supply
features, a suitable adapter must be fitted.
IF THE VOLTAGE CHANGE SWITCH PO-
SITION, THE TYPE OF SOCKET AND THE
POWER SUPPLY ARE CONSISTENT, YOU
MAY PROCEED WITH THE SWITCH ON SE-
QUENCE.
CAUTION: Check that the power cord is
properly connected.