The following instructions should be read by a qualified technician to ensure that the appliance is installed, regulated and
serviced correctly in compliance with current standards.
Important: Remember to unplug the appliance from the mains before making adjustments or doing maintenance.
P P P P P ositioning
ositioning
ositioning
ositioning
ositioning
Important: This unit may be installed and used only in permanently ventilated rooms in compliance with current National
Regulations. The following requirements must be observed:
a) The room must be equipped with an exhaust system that vents the combustion fumes to the outside. It may consist
of a hood or an electric fan that automatically starts each time the appliance is turned on.
b) The room must also have a system to permit proper air circulation, needed for combustion to occur normally. The
flow of air needed for combustion must not be less than 2 m
take air directly from the outside by means of a pipe with an inner cross section of at least 100 cm
not be able to be accidentally blocked. For those appliances not equipped with a safety device for accidental flame loss,
the ventilation apertures must be increased by 100%, with the minimum being 200 cm
provide the air needed for combustion by indirect means, i.e. from adjacent rooms fitted with air circulation tubes as
described above. However, these rooms must not be common rooms or bedrooms. (Fig. B).
c) Intensive and prolonged use of the appliance may result in the need for supplemental air circulation, e.g. opening
windows or increasing mechanical venting (if present).
d) Liquified petroleum gas is heavier than the air and, therefore, settles downwards. Thus, rooms containing LPG
cylinders must also be equipped with apertures to the outside for ventilation of gas in the case of leaks. LPG cylinders
must not, therefore, be installed or stored in rooms or storage areas that are below ground level (cellars, etc.) whether
they are partially or completely full. It is a good idea to keep only the cylinder being used in the room, positioned so that
it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. ) which are able to increase the
temperature of the cylinder above 50°C.
Le
Le
Lev v v v v elling
Le
Le
elling
elling
elling Y Y Y Y Y our
elling
our
our
our A A A A A ppliance
our
ppliance (only on certain models)
ppliance
ppliance
ppliance
4 support feet which are adjusted using screws are located in the lower part of the cooker. These level off the oven when
necessary. It is essential that the cooker be standing level.

Installation

Flue or Branched Flue System
(only for cooking appliances)
Detail A
A
Examples of Ventilation Openings
Comburent Air
Fig. A
Directly to the Outside
3
/h per kW of installed power. The air circulation system may
Adjacent
Room to
Room
be Ventilated
Increased Opening Between
Door and Floor
Fig. B
- 20 -
2
; the opening must
2
(Fig. A). The system can also