4.
ELECTRICAL CONNECTIONS
A limentazione
Power supply
ATTENTION: Make a jumper all the N.C. contacts if not used. Use only DITEC accessories and safety devices.
4.1 Controls
Control
1
5
N.O.
STEP-BY-STEP
OPEN WITH
AUTOMATIC CLOSING
OPEN WITHOUT
AUTOMATIC CLOSING
1
8
N.C.
REVERSAL SAFETY CONTACT The closing of the contact during the closure manoeuvre causes the
1
9
N.C.
STOP
TRANSF.
F1
BATK1
Luce di cortesia
Nero / Black
Blu / Blue
ENC
Motor
24V=
Function
With DIP1=OFF the closure of the contact activates the sequence:
open-stop-close-open.
Note: if automatic closing is enabled, the STOP is not permanent but at
a time that is set by TC.
With DIP1=ON and the automatic closure on, the closure of the contact
activates an opening operation.
With DIP1=ON and TC=MAX, the closure of the contact activates an
opening operation.
With the automation idle, the closure of the contact performs the operation
opposite to that prior to the stop.
movement to invert (re-opening).
The opening of the contact causes the movement to stop and the auto-
matic closure to be disabled.
Resetting the command, the door remains still until a 1-5 command or
a radio command is received.
OPEN
24 V~
BAT
JR4
SO
JR3
Courtesy light
JR2
-M
+M
Only GLOBE10
15 14
13
0 1 5 8 9
19
70R-71R
ANT
PRG
SIG
COM
ON
Only GLOBE1 0
OFF
1 2 3 4 5 6
POWER
ALARM
SA
R1
TC
Description
GB
GLOBE - IP1839