Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
cleaned at least once a month. If there is a great amount
of powder in the air, the filter must be cleaned once a
week, or even every day. Pull the front panel out and
clean the filter. If necessary, you may slightly knock all
over the filter, use a vacuum cleaner to remove bigger
pieces of dirt or even wash the filter in warm clean water
(≤40% with some neutral detergents) and then dry it.
6. TROUBLE - SHOOTING
►►
UNIT DOES NOT WORK
► Analysis
1.Power cut
2.Switch off
3.Unplugged
4.Fuse melted
5.Tank full
► Solution
1.Power on
2.Switch on
3.Plug on
4.Exchange fuse
5.Empty the tank and replace it
DEHUMIDIFIES IN INADEQUATELY
► Analysis
1.Filter choked by dirt
2.Some barrier
in air inlet or outlet
3.Door or windows open
4.Refrigerant leakage
► Solution
1.Clean the filter
2.Remove the barrier
3.Close the door and windows and
seclude from the sunshine
4.Contact the manufacturer or seller

WATER LEAKAGE

► Analysis
1.The unit is inclined
2.Drainer choked
► Solution
1.Adjust the unit to be stable
2.Pull out the panel and remove the barrier
STRANGE NOISE
► Analysis
1. Until instable
2. Filter choked
► Solution
1.Place the unit stably
2.Clean the filter
► When above malfunctions occur and they could not
be removed, please contact the supplier or seller, do not
disassemble the machine yourself.
► When the unit starts or stops running, it makes cer-
tain noises of refrigerating circulation, which should not
be considered as a malfunction.
► Hot air coming from the air outlet is normal.
►►
INSTRUCTION ON MALFUNCTION CODES:
The unit analyzes malfunction automatically and displays
the code on the humidity window.
MALFUNCTION DISPLAY
► Sensor of humidity
MALFUNCTION DISPLAY
► Sensor of refrigeration pipeline
E1
E2
en
it
de
es
fr
nl
da
fi
no
sv
pl
ru
cs
hu
sl
hr
lt
lv
et
ro
sk
bg
uk
zh
SI
SK
TR
UA

Publicité

Table des Matières
loading

Table des Matières