Abicor Binzel ABIPLAS CUT 200 W Mode D'emploi page 35

Masquer les pouces Voir aussi pour ABIPLAS CUT 200 W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
ABIPLAS
CUT 200 W/MT
®
ABIPLAS
CUT
Type of wear part
Application process
Type of use
Pilot current
Rated current and corresponding duty cycle
Type of gas
Operating pressure (flow pressure)
Torch inlet pressure
Plasma air
Air flow rate measured with 1.8 mm nozzle
bore
Soft start
Gas post flow delay
Type of voltage
Voltage rating
Type of cooling
Protection type of the machine-side
connections
Electrical control device rating
Tab. 3
Product-specific torch data (EN 60 974-7)
1Special wear parts are for ignition-critical power sources and labelled with an 'X'.
Max. supply temperature
Min. flow rate
Inlet pressure
Coolant conductance
Tab. 4
Torch cooling information
3 Product description
200 W
200 W MT
Standard
Plasma cutting/gouging
Manual/automatic
15 - 27 A (max. 29 A)
200 A/100%
Compressed air
3.5 - 4.5 bar
Approx. 39 l/min
≥15 l/min
> 20 sec
DC direct voltage
Peak value of 500 V (voltage class M)
Liquid
IP3X (EN 60 529) (200 W)
IP2X (EN 60 529) (200 W MT)
42 V/0.1-1 A
45°C
0.9 l/min
min. 2.5 bar, max. 4 bar
max. ≤ 30 µS/cm
1
Special
160 A/100%
3.5 bar
Approx. 21 l/min
If available
≤15 l/min
EN - 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Abiplas cut 200 mt

Table des Matières