6.
See Figure 4-4. Remove the screw located at the bottom of
the front cover.
7.
See Figure 4-5. Hold the front cover. Flip upward and then
shift leftward to separate the front cover from the charger.
8.
Remove the compartment cover.
9.
See Figure 4-6. Use appropriate copper wire with listed
pressure terminal connectors, such as ring and fork types,
on the end of the conductor before attachment to the
terminal blocks. Keep enough length of wire to facilitate
installation. Connect each terminal to the correct terminal
19 lb•in (2.2 N•m).
input block connector in the compartment and torque to
Model
EL -51866-40XX
EL -51866-30XX
Installation and Operating Instructions | Power Max 2 Charging Station | 7 | en
Figure 4-4.
Figure 4-5.
Copper Wire Type
No. 6 AWG, 90 °C
No. 8 AWG, 75 °C or 90 ºC
Figure 4-6.
Note: Choose appropriate conduit in accordance with
all applicable state, local, and national electrical codes
and standards.
10. See Figure 4-7. Replace the compartment cover
and torque to 8.7 lb·in (1.0 N·m).
Figure 4-7.
11. Replace the front cover by aligning the hinge on
the top. Secure the front cover by the bottom
screw, torque to 10.4 lb·in (1.2 N·m).
12. See Figure 4-8. Place the charger cable properly.
Figure 4-8.
579367 | REV A | 25.07.2016