en | 6 | Installation and Operating Instructions | Power Max 2 Charging Station
4

Installation

4.1 Important SAFETY WARNINGS and
Instructions
IMPORTANT SAFETY INSTRUCTIONS. SAVE
THESE INSTRUCTIONS.
WARNING
Danger of electrical shock or injury. Turn off
power at the panel board or load center before
working inside the equipment or removing any
component. Do not remove circuit protective
devices or any other component until the
power is turned off.
The Power Max 2 Charging Station shall be installed only
by a licensed contractor, and/or a licensed electrician in
accordance with all applicable state, local and national
electrical codes and standards.
Before installing the Power Max 2 Charging Station, review
this manual carefully and consult with a licensed
contractor, licensed electrician, and trained installation
expert to ensure compliance with local building practices,
climate conditions, safety standards, and state and local
codes.
Use appropriate protection when connecting to the main
power distribution cable.

4.2 Grounding Instructions

The Power Max 2 Charging Station must be connected to a
grounded, metal, permanent wiring system; or an equipment
grounding conductor must be run with the circuit conductors
and connected to the equipment grounding terminal or lead on
the product.

4.3 Recommended Tools

The following tools are recommended for the Power Max 2
Charging Station installation:
}
Vendor supplied accessories and components:
Mounting bracket
Mounting template
Cable hanger bracket (optional)
Torx T30 bolts (x2) for securing the Power Max
2 Charging Station to the mounting bracket
1/4-in. expansion bolts (x3)
No. 8 wood screws (x3)
Terminal crimps (x3)
}
Installer-supplied components:
Conduit of appropriate trade size for power wire
NEMA 6-50R receptacle
}
Recommended tools:
Torx T30 screwdriver
Torx T20 screwdriver
Phillips #2 screwdriver
Flathead slotted #5 screwdriver
Terminal crimper
579367 | REV A | 25.07.2016
4.4 Installing the Power Max 2
Charging Station
1.
See Figure 4-1. Use the supplied template to locate the
mounting bracket above the electrical receptacle.
Figure 4-1.
Note: Follow applicable accessibility requirements for the
mounting position. The unit shall be mounted at a suficient
height from grade such that the height of the storage means
is located between 600 mm (24 in.) and 1.2 m (4 ft) from
grade per NEC Article 625.
2.
Secure the mounting bracket and the optional cable
hanger bracket to the wall with appropriate bolts as
follows:
For masonry walls use 1/4-in. expansion bolts and
torque to 78 lb•in (8.8 N•m).
For inished walls supported by wood studs use #8
wood screws of 2 in. or above screw length and
torque to 26 lb•in (3 N•m).
3.
See Figure 4-2. Align the screw holes of the mounting
bracket with the Power Max 2 Charging Station. Install
and secure the Power Max 2 Charging Station on the
mounting bracket with the two (2) Torx T30 screws
supplied. Torque to 13 lb·in (1.5 N·m).
Figure 4-2.
4.
See Figure 4-3. Secure mounting tab to wall.
Figure 4-3.
5.
If installed above a receptacle, the installation is
complete. For hardwired installation, continue to Step 6.