GB
MAINTENANCE, TROUBLESHOOTING AND REPAIR
CLEANING AND ORDER
The workstation must be cleared of objects that could obstruct the free movement of the operator, as
moving springs in and out of the spring compressor. The floor around the workstation must be cleared
of objects or fluids that could make the operator slip or fall.
SERVICE AND MAINTENANCE
Shut off the engine before service or maintenance.
After completing service or maintenance make sure that shields and safety measures are in place and
working.
Failure to follow this warning can cause serious injury.
What?
Tubes
Hydraulic oil level
(
Mobil DTE 10 Excel
Series)
Hydraulic fittings
Bolts fastening the jaws
Column
Sliding block
(Super Lube
Aerosol)
®
Moving parts
GUARANTEE
This tool carries a guarantee according to current law. Subject to change without notice.
TERMINATION OF USE
The machine is separated and sorted and disposed of according to local regulations.
When?
Monthly
Monthly
Monthly
Every use
Monthly
Monthly
Monthly
10
How?
Check for visible wire mesh and leaks.
Replace any worn or damaged tubes before
starting the engine.
Check that oil level is between the 2 strokes
on the dipstick. If necessary, add sufficient
amount of low freezing point hydraulic oil
Check for cracks and leaks. Replace any
damaged fittings before starting the engine
Check for loose bolts
Lubricate the column with
lithium grease
Lubricate the sliding block
with grease
Remove any dirt