SEAS ONAL MAINTE NANCE
(implemented by the DEALER )
Consists in:
• Clean the boiler-stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber
and the relative compartment
• Clean fans, verify mechanical and clamp loosening
• Clean smoke channel (replace seals on smoke exhaust pipe)
• Clean smoke duct
• Check the expansion tank
• Check and clean the circulator
• Clean smoke extraction fan compartment.
• Clean smoke check thermocouple.
• Empty the pellet hopper and clean the base with the vacuum
cleaner.
• Clean, inspect and scrape any residue from the ignition resistan-
ce compartment and if necessary, replace it
• Visually inspect the electrical wires, connections and power cable
• Check play of the screw-gear motor group
• Clean the pellet hopper and check loosening of the feed screw -
gear motor assembly
• Replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10
minutes and shutdown
If the boiler-stove is used very frequently, it is advisable to
clean the smoke channel and the fume duct every 3 months.
ATTENTION !!!
After implementing a normal cleaning procedure, INCOR-
RECT coupling of the upper (A) (fi gura 1) and lower
(B) (fi gura 1) combustion chambers can compromise the
stove's performance. Before igniting the stove, make sure
the combustion chambers are correctly paired as indicated
in (fi g. E) without ash or unburnt material present on the
support perimeter.
We remind you that using the stove without cleaning the mel-
ting pot, may cause a sudden ignition gas inside the combu-
stion chamber with the consequent breaking of the glass
CLEANING THE SMOKE DUCT
• When the stove is cold and in stand-by shake the lever for
cleaning (pag.47); open the door and remove the inspection panel
sheet (4 - fi g. C), complete with silicone gasket (5 - fi g. C), fi xed
with wing nuts.
Clean the silicone gasket and vacuum resid from the fl ue pipe
(6 - fi g. C).
The thermo stove comes with a spare silicone gasket.
The amount of residue will depend on the type of fuel and sy-
stem.
Failure to carry out this cleaning procedure may cause the boiler-
stove to block.
ONCE THE PROCEDURE IS IMPLEMENTED, ENSURE
THATTHE INSPECTION HATCH IS CLOSED PRO-
PERLY (4 fi g. C).
MAINTENANCE
fi g. 1
fi g. 2
fi g. C
- 48
-
A
B
5
4
6