Operating Manual SATA filter 100 / 101 / 103 prep
7.

Assembly

7.1. SATA filter 100 prep and 103 prep
• Install mounting bracket [1-2] on the filter
• Install the filter vertically on the wall with screws, thus ensuring full func-
tionality of the automatic condensate drain valve
• Connect air inlet G ½" (internal thread) to compressed air line with
detachable bolted connection
• Slide condensate drain hose [1-10] over the drain valve [1-9]; put hose
end into a suitable collection container (not included in delivery).
Information!
• Mount shut-off tap in front of the filter, e.g. Art. No. 10934 (not in-
cluded in delivery), allowing easy and safe filter maintenance.
7.2. Retrofit SATA filter 100 prep to filter 103 prep
[2]
For retrofitting with an activated charcoal filter, a SATA filter 101 prep [C]
(Art. No. 157412) is required:
• Depressurize filter (close shut-off tap)
• Loosen [2-1] air outlet module [D] from the dual-stage filter combina-
tion [A]/[B]
• Screw on [2-2] SATA filter 101 prep [C]
• Screw on [2-3] air outlet module [D]
8.

Use

Use solvent-resistant, antistatic, undamaged, technically flawless com-
pressed air hoses with a continuous pressure resistance of minimum 10
bar, e.g. Art. No. 53090!