Operating Manual SATA filter 100 / 101 / 103 prep
• When the compressed air is heavily contaminated, the filter
cartridges have to be exchanged in shorter intervals!
• Saturated filter cartridges may cause quality problems during paint
jobs. Furthermore, using a supplied-air respirator could become harm-
ful, causing permanent health damage and even death!
• Depressurise filter (close shut-off tap)
• Unscrew [3] the respective filter housing with the pin spanner included
in the delivery.
• Remove condensate cyclone separator [4-1] from the filter stage
[A], remove and check insert as well as sintered filter [4-2]. Clean or
replace if necessary
• Remove [4-3] and replace fine or activated charcoal cartridge on filter
stages [B] and [C]
• Installation has to be carried out in reverse order. Please make sure
that the filter cartridges are installed in the correct order. Coloured
markers (yellow = sintered filter [A], blue = fine filter [B], black = acti-
vated charcoal filter [C] allow clear identification [4-4]. Marking rings
are located on the threaded rods of the filter stages [B] and [C].
• During installation, please ensure proper seat and undamaged O-rings!
Note!
Please observe local regulations for the disposal of filter cartridges!

11. Troubleshooting

Malfunction
Pressure cannot be
properly adjusted
Warning! Attention!
Cause
Insufficient inlet pres-
sure
Pressure regulation
valve at air outlet mod-
ule is defective
Corrective action
Increase inlet pressure
Exchange air outlet
module [D], Art. No.
148239