LENS (RE)PLACEMENT
Always unplug the unit before you replace the lenses! DO NOT TOUCH THE LED
LAMPS!
HIGH
POWER
LEDs
ELECTRICITY!!! You can easily destroy the LEDs by simply touching them!
 Switch off the main supply and unplug the unit.
 Remove the 4 screws to open the lens compartment and protective glass( A on the picture below)
 Remove the 4 screws that keep the black lens cover plate in place and remove the metal plate. (B on the
picture)
 GENTLY remove the original lens (C on the picture) DO NOT TOUCH THE LEDs!!!
 Put the lens with different beam angle gently in place. Please note that the beam angle is indicated in the
center of the lens.
 Fasten the metal lens cover with the 4 screws.
 Put the protective glass back in place and fix it with the 4 screws.
 Done!

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable (number 3 on the picture) that can hold 12 times the weight of the
device when installing the unit. This secondary safety attachment should be installed in a way that no part
of the installation can drop more than 20cm if the main attachment fails.
BRITEQ
®
OPERATION MANUAL
ARE VERY
SENSITIVE FOR
ELECTROSTATIC
3/65
BT-36L1
ENGLISH
 The device should be well fixed; a free-swinging
mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may
result in overheating.
 The operator has to make sure that the safety-
relating and machine-technical installations are
approved by an expert before using them for the first
time. The installations should be inspected every
year by a skilled person to be sure that safety is still
optimal.
1. Optional Quick Clamp
2. Special omega clamp (included)
3. Optional safety cable
HOW TO SET UP THE UNIT

CONTROL PANEL:

1. DISPLAY shows the various menus and the selected functions.
2. LEDS
DMX
On
MASTER
On
SLAVE
On
SOUND
Flashing
3. BUTTONS
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
4. REMOTE CONTROL INPUT: Used to connect a simple CA-8 hand controller while the unit is used in
standalone or master/slave mode.
5. SENSITIVITY: Used to adjust the sensitivity of the micro when the unit is used in standalone or
master/slave mode.
6. DMX INPUT/OUTPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link
the units together.
7. MAINS INPUT: with IEC socket and integrated fuse holder, connect the supplied mains cable here.
BRITEQ
®
OPERATION MANUAL
DMX input present
Master mode
Slave mode
Sound activation