Technical data
4
Technical data
Type
Design
Power
Electrical connection
Minimum cable cross-section
Rated current
Fuse protection
Water connection thread
Supply temp. max.
Warm water output at supply
temp. of 12 °C to 38 °C
Protection type
Switch on flow pressure
(without flow rate limiter)
Switch on flow
Switch off flow
Flow limit at
Weight
Application area in water:
specific electric resistance
at 15 °C
Rated pressure
Plug-in ready
Fixed connection
Energy efficiency class
Load profile
Annual energy consumption
Daily energy consumption
Sound power level
Hot water heating energy
efficiency
14
TR4000 4
ET
TR4000R 4
ET
Undersink
pressurised pressurised pressurised pressurised pressurised pressurised
[kW]
3,6
[V]
230
[mm²]
1,5
[A]
15,7
[A]
16
[Inch]
G 3/8
[°C]
20
[l/min]
1,9
IP
24
[bar]
< 0,25
[l/min]
1,8
[l/min]
1,6
[l/min]
2
[kg]
1,1
[Ωcm]
≥ 1 300
[MPa (bar)] 1,0 (10,0)
–
A
XXS
[kWh]
467
[kWh]
2,145
[dB]
15
[%]
39,4
TR4000 5
TR4000 6
ET
ET
Undersink
Undersink
4,5
6
230
230
2,5
4
19,1
26
20
32
G 3/8
G 3/8
20
20
2,4
3,2
24
24
< 0,25
< 0,25
1,8 / 1,9
1,8 / 2,1
1,6 / 1,7
1,6 / 2,0
2
3
1,1
1,1
≥ 1 300
≥ 1 300
1,0 (10,0)
1,0 (10,0)
–
–
A
A
XXS
XXS
470
470
2,150
2,154
15
15
39,3
39,2
TR4000 | TR4000R – 6 720 876 021 (2017/11)
TR4000 8
TR4000 6
ET
EB
Undersink
Over-sink
7,2
6
230
230
4
4
31,3
26
32
32
G 3/8
G 1/2
20
20
3,9
3,2
24
24
< 0,25
< 0,25
1,8 / 2,3
1,8 / 2,1
1,6 / 2,2
1,6 / 2,0
4
3
1,1
1,1
≥ 1 300
≥ 1 300
1,0 (10,0)
1,0 (10,0)
–
–
A
A
XXS
XXS
471
470
2,161
2,154
15
15
39,1
39,2
TR4000 8
EB
Over-sink
7,2
230
4
31,3
32
G 1/2
20
3,9
24
< 0,25
1,8 / 2,3
1,6 / 2,2
4
1,1
≥ 1 300
1,0 (10,0)
–
A
XXS
471
2,161
15
39,1