INSTALLATION MANUAL
CAA480A
Elevator Controller
Figure 11: Fire Control (FC) Override Jumper:
FC OVERIDE
C
ERSED
LAY
T
!
If you are employing Fire Control with the CAA480A, be sure to wire the fl oor control relays using
the Fail Safe method. Refer to "Fail-Safe" on page 8 for more information.

12] DIP SWITCH SETTINGS

SETTING THE CAA480A'S FLOOR ADDRESS (DEFAULT: OFF, OFF, OFF, OFF)

When installing the CAA480A elevator controller you must assign it to a door and fl oor
address. This address advises the CT-V900-A controller which group of 16 fl oors it will
be controlling and for which elevator car. The CAA480- A's fl oor address is set through
four DIP switches: ADDRESS 1, ADDRESS 2, ADDRESS 4 and ADDRESS 8.
To set the CAA480A's fl oor address, follow Table 1 (below) and turn on the appropriate
DIP switches. Refer to Figure 12 and to Figure 13 for more details.
Door 1 from the CT-V900-A is used for Elevator Car 1 and Door 2 from the CT-V900-A is used
for Elevator Car 2. If connecting more than one CAA480A to a CT-V900-A controller, make sure
that you do not assign more than one CAA480A with the same fl oor address. Each CAA480A
(up to 8) assigned to the same CT-V900-A must have different fl oor addresses.
cdvi.com
14
cdvigroup.com
+12V
GND
GND
FC
FC
Fire Control Override Jumper Settings
ENABLED
FC OVERIDE
DISABLED
FC OVERIDE