INSTALLATION MANUAL
CAA480A
Elevator Controller
Figure 7: Security Enabling Control:
Elevator Car
Card Reader 1
Button's "common"
terminal
Elevator car
Button's input
Floor Button
Terminal

9] JUMPER SETTINGS

HIGH/LOW E-BUS IMPEDANCE JUMPERS (DEFAULT "HIGH")

These jumpers adjust the E-BUS impedance. These jumpers are only applicable
if the CAA480A is connected to the CT-V900-A revision 200 or higher.
Normally, both jumpers should be set to "HIGH" unless you are employing a set mode
as described in the CT-V900-A Installation Manual. Refer to Figure 8.
Elevator
Control
System
Elevator Control System
Elevator Control
Microprocessor
Floor Security Input
"common" terminal
Floor Security Input
To
Floor Security input
terminals
CA-A480-A
Elevator
Controller
To
Floor Button
relays
(N.C. Floor Control Relay connection)
terminal
(N.O. Floor Control Replay connection)
E-BUS
CT-V900-A
Controller
Card Reader 2
for second
Elevator Car
Fail-safe Connection Method
CA-A480-A Elevator Controller
ADRESS 1
COM1
ADRESS 2
ADRESS 4
NO1
ADRESS 8
NC1
RLY COMMS
COM2
RLY OFF/ON
DRM ENABLED
NO2
PWR OFF/ON
OR
Fail-secure Connection Method
CA-A480-A Elevator Controller
COM1
NO1
NC1
COM2
NO2
cdvi.com
cdvigroup.com
To next
CA-A480-A
Elevator
Controller
11