INSTALLATION MANUAL
CAA480A
Elevator Controller
CT-V900-A
Controller
E-Bus
10] 350mA/700mA BATTERY CHARGING JUMPER (DEFAULT "350mA")
This jumper allows you to select the charging current for the backup battery
of the CAA480A. Charging the battery at 350mA will take longer, but consumes
less power from the CAA480A. Charging the battery at 700mA takes less time,
but consumes more power from the CAA480A. Refer to Figure 10.
Figure 10: 350mA/700mA Battery Charging Jumper:
+
350mA/700mA
11] FIRE CONTROL (FC) OVERRIDE JUMPER (DEFAULT "ON")
This jumper determines the CAA480A's fi re control override inputs. When this jumper
is "ON", even if there is a fi re circuit connected to the CAA480A's fi re control inputs
("FC" terminals), the CAA480A will ignore any signals coming to the "FC" terminals.
Refer to Figure 11 for more details. For more information on the CAA480A's fi re control
capabilities, refer to "Fire Control" on page 16.
!
If you are not using the CAA480A's Fire Control terminals then the FC Override jumper should be
in the "ON" position. This will allow for full power to be supplied to the fl oor control relays.
Sample E-BUS EOL Jumper Settings
CA-A480-A
ELevator
Controller
CA-A480-A
E-Bus
EOL=OFF
+
+
+
CA-A480-A
CA-A480-A
ELevator
ELevator
Controller
Controller
CA-A480-A
CA-A480-A
E-Bus
EOL=OFF
EOL=OFF
Battery Charging Jumper Settings
350mA
350mA/700mA
CA-A480-A
ELevator
Controller
CA-A480-A
E-Bus
EOL=ON
700mA
350mA/700mA