For the fitter and kitchen
specialist.
Important notes:
Please ensure that you dispose of the
packaging responsibly.
Caution: the appliance may only be
connected and started up by an
authorized specialist.
Mains connection cable H05VV-F must
be used.
For voltage and rated consumption,
see rating plate.
The rating plate of the hob is located at
the front, below on the body of the hob.
The rating plate for the gas built-in facia
is located on the connection box.
The electrical safety of the appliance is
only assured if the domestic protective
conductor system is installed according
to regulations.
Whenever assembly or repair work is
carried out the appliance must be
deenergized.
Connectable built-in hob:
M-AD11-N; M-AD13-N.
Installation:
Only install in deenergized condition.
For example, by turning off the domestic
main fuse.
The cutout in the worktop must be
complete (see assembly instructions for
built-in hob).
The gas built-in facia must be installed
before the hob.
1. Execute the cutout in the wooden front
(max. 90 mm x 525 mm).
(For cutout dimensions in the worktop,
see assembly instructions for built-in
hob).
18
Assembly Instructions
Furniture ranges
The built-in gas facia can be fitted to the
cooker conversion units of any kitchen
furniture range. Veneers or plastic laminates
must feature heat-resistant adhesive
(90°C). If plastic laminate or adhesive is not
sufficiently heat-resistant the unit's laminate
might deform or lift off.
The appliance corresponds to protection
class Y according to test specifications for
heat exposure.
For the gas built-in facia use a base unit for
switch boxes with an intermediate level.
Caution: The appliance may only be
installed with one side beside a full-
height cabinet or wall. On the respective
opposite side the height of an adjacent
unit may not exceed the height of the
work surface in which the hob is
installed.
Distances from hob to full-height cabinet
and from hob to rear wall must
correspond to the assembly instructions
for the built-in hob, observing the
protection class for heat exposure given
in the assembly instructions.
30-50
525
90
20
min.20
max.
16
max.
90
min.
6
16 min.
25 max.