Left Side Venting
1. Mark cabinet side for left side vent hole location.
A
B
A. 31³⁄₁₆" (79.2 cm) from top of cabinet
B. 18" (45.7 cm) from back wall
2. Mark and cut a 5½" (13.9 cm) diameter hole in the cabinet
side.
A
B
A. 5½" (13.9 cm) diameter hole
3. Mark and cut a 14" x 11" (35.6 x 27.9 cm) opening in the floor
of the cabinet.
A
B
A. 11" (27.9 cm) from front of cabinet
B. 14" (35.6 cm) from left side of cabinet
Top View
4. Remove 4 locknuts on the motor side of the blower and
remove the bracket.
View from Motor Side of Blower
A
A. Electrical connector
5. Lift and rotate the motor 180° to reposition the electrical
connection.
A. Electrical connector
6. Rotate bracket 90° and secure with 4 locknuts.
A
15