MEDC PBE Manuel Technique page 7

Declencheur à bouton poussoir
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.0 CERTIFIC TION/ PPROV LS
Certified to: EN60079-0, EN60079-1 & EN60079-7 (BGE/BG2E)
EN60079-0, EN60079-1, EN60079-7 & EN60079-31 (PBE)
Ex de unit TEX certification No. B S02 TEX2105X
BGE/BG2E:
Standard: Ex d e IIC T6 Gb (-40°C to +70°C)
With optional LED: Ex d e mb IIC T6 Gb (-35°C to +70°C)
With optional resistor: Ex d e mb IIC T4 Gb (-40°C to +70°C)
With optional LED and resistor: Ex d e mb IIC T4 Gb (-35°C to +70°C)
PBE:
Standard: Ex d e IIC T6 Gb (-40°C to +70°C)
Ex tb IIIC T85°C Db (-40°C to +70°C)
With optional LED: Ex d e mb IIC T6 Gb (-35°C to +70°C)
Ex tb IIIC T85°C Db IP66 (-35°C to +70°C)
With optional resistor: Ex d e mb IIC T4 Gb (-40°C to +70°C)
With optional LED and resistor: Ex d e mb IIC T4 Gb (-35°C to +70°C)
The certificate and product label carry the TEX group and category marking:
II 2 GD
Where:
Signifies compliance with TEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 and Zone 2 area
G
Signifies suitability for use in the presence of gases
D
Signified suitability for use in the presence of dust
The 'D' category marking is applicable on the PBE version only
11/13
Ex tb IIIC T120°C Db IP66 (-40°C to +70°C)
Ex tb IIIC T120°C Db IP66 (-35°C to +70°C)
© MEDC 2013

Publicité

Table des Matières
loading

Table des Matières