Type 2030, 2031, 2031 K, 2032,
2033, 2037
8.2.5. Preparatory work
→
Clean pipelines (sealing material, swarf, etc.).
→
Support and align pipelines.
Devices with welded or glued body:
Before welding or gluing the body, the actuator and the
diaphragm must be removed.
8.3. Installation
If used in an aggressive environment, we recommend con-
veying all free pneumatic connections into a neutral atmo-
sphere with the aid of a pneumatic hose.
WARNING!
Risk of injury from improper installation!
Non-observance of the tightening torque is dangerous as the
device may be damaged.
• Observe tightening torque during installation (see "Tab. 9: Tight-
ening torques for diaphragms").
Installation
8.3.1. Devices with welded or glued body
NOTE!
To prevent damage!
• Before welding or gluing the body, the actuator and the dia-
phragm must be removed.
Remove actuator and diaphragm from the body:
Procedure for control function A
→
Pressurize lower control air connection with compressed air
(value as indicated on the type label) (see "Fig. 29: Control air
connection").
This is required to detach the diaphragm without damage from
the body.
→
Loosen fastening screws crosswise and remove actuator
together with diaphragm from the body.
→
Weld or glue body into the pipeline.
Procedure for control functions B and I
→
Loosen fastening screws crosswise and remove actuator
together with diaphragm from the body.
→
Weld or glue body into the pipeline.
Mount actuator and diaphragm on the body:
→
After welding or gluing in the body, smooth the body surface by
grinding if required.
→
Carefully clean the body.
english
25