ENGLISH
Make sure that all units are connected to the mains.
Each light effect in the chain needs to have its proper starting address so it knows which commands from the
controller it has to decode. In the next section you will learn how to set the DMX addresses.
How to set the DIP-switches to obtain the right starting address:
On the back of the Phaeton you will see that each of the first 9 DIP-switches corresponds to certain value:
Dip
#1
#2
#3
#4
#5
Value
1
2
4
8
16
You can combine the values of these switches to become any starting address between 1 and 512:
Begin address = 01
switch 1=ON
Begin address = 05
switch 1+3=ON
Begin address = 09
switch 1+4=ON
Begin address = 13
switch 1+3+4=ON
...
Begin address = 62
switch 2+3+4+5+6=ON
DMX-CONFIGURATION :
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
JB SYSTEMS
®
OPERATION MANUAL
#6
#7
#8
#9
32
64
128
256
values: 1
values: 1+4 = 5
values: 1+8 = 9
values: 1+4+8 = 13
values: 2+4+8+16+32 = 62
5/36
PHAETON
ENGLISH
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 230V, 50Hz
Fuse:
250V 10A slow blow (20mm glass)
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
Lamp:
Circular HX185 800W/240V
Size:
374 x 312 x 246 mm
Weight:
7,6kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
®
OPERATION MANUAL
6/36
PHAETON