Inner Platilon liner
D
Outer cover
E
Hook and loop adapter (not shown)
The best way to avoid problems related to pressure sores is to
understand their causes and your role in a skin management
program. Your therapist and physician should be consulted
if you have questions regarding individual limitations and
needs. All cushions should be selected carefully. Working
with your therapist and physician is the best way to ensure
that a cushion choice matches your individual needs. As
the needs of the individual become more complex, cushion
evaluation becomes more important.
The cushion A uses a combination of a moulded foam base
B and dual layer clinical fluid sac C to provide the highest
level of skin protection for users with very high risk of skin
breakdown.
Clinical Fluid Sac
The clinical fluid sac utilises silicone in a unique dual-layer
design placed in the ishcial/sacral areas to help prevent
bottoming out.
Inner Liner and Outer Cover
The inner liner D is moisture resistant to protect the
foam. The standard outer cover E is water resistant and
breathable. Regular cleaning and inspection of the covers is
recommended, see 7 Maintenance, page 5 .
3.2 Intended Use
This cushion is intended to be used in an armchair or
wheelchair as part of an overall pressure injury prevention
program of care.
There are no contraindications known.
3.3 Symbols on the Product
European
Conformity
Manufacturer
European
representative
Lot number
Machine wash
(maximum
temperature see
label)
Do not iron
Do not bleach
1633710-A
Medical Device
Date of
manufacture
Read user manual
Maximum user
weight
Tumble dry low
heat
Do not dry clean
Avoid burning
cigarette
Do not put near
flame
Orientation label
(depending on
product)
4 Accessories
4.1 Installing Accessories
Optional Matrx Libra accessories are available separately and
allow the cushion to be adjusted where necessary to meet
the specific positioning needs of the end user.
F
Abductor
G
Clinical fluid supplement sac
Lateral side wedge
H
I
Cut to size anterior (front) wedge (J)
Anterior (front) wedge
J
K
RF/LR tapered wedge
L
LF/RR tapered wedge
Installing Abductor Support
1. Remove the outer cover and inner liner.
2. Align the hook strip M on the abductor support F with
the loop N strip on the top of the foam base B at the
desired depth.
3. Press down to secure the abductor support to the foam
base.
4. Re-install the inner liner and outer cover.
Installing Clinical Fluid Supplement Sac
1. Remove outer cover and inner liner and unfasten the
hook and loop strips from the side and/or rear of the
clinical fluid sac C where you wish to install the clinical
fluid supplement sac(s) G.
2. Locate the small pocket/slot O on the underside of the
clinical fluid sac.
Do not pierce or
cut
Fig. 4-1
Fig. 4-2
Fig. 4-3
3