GB
1. Important notes
The fan may only be operated at the rated volt-
age specified on the rating plate.
Electrical and appliance installation must be
carried out in accordance with the valid regula-
tions, in particular DIN VDE 0100 with the perti-
nent parts.
MAICO appliances are in compliance with valid
safety legislation. Electrical connection and
repairs may only be carried out by suitably qual-
ified experts.
Motor with thermal overload protection.
The motor is switched off in the case of thermal
overload. It is automatically turned on again
after having cooled off. Determine and correct
the cause of trouble.
Before removing the motor, take off the swivel
lever
and the eccentric disc
Max. permissible ambient temperature +40°C.
Circuit diagram for speed control on request.
The installation must be equipped with a mains
disconnecting device with a contact opening of
at least 3,5 mm at each pole.
For all type-related data, see the rating plate /
valid MAICO catalogue.
The fan is designed in accordance with VDE
safety requirements within the scope of the
Equipment and Product Safety Act and the valid
stipulations of EC directives.
2. Determining the swivel angle
The swivel lever
ment of 90°. For other swivel movements, it must
be fixed in a different corresponding hole. For this
purpose, the eccentric disc
(left-hand thread).
Maximum deflection of the protective cage
12.5mm.
3. Electrical installation, surface mounting, flush
mounting
Surface mounting: Use cable grommet
Flush mounting: Break through bushing in the foot
of the retaining arm
.
is mounted for a swivel move-
can be unscrewed
.
.
4. Installation
Pull the cap
off the connecting chamber. (To do
this when carrying out subsequent work apply two
screwdrivers at two opposite corners at the front
and back and lever off).
Move the connecting cable with terminal strip and
capacitor out of the way to afford access to the fix-
ing holes.
In the case of flush mounting, guide the mains
cable through the borehole into the connecting
chamber.
Screw the fan firmly to the ceiling or wall with
screws and dowels or using similar suitable fasten-
ing material.
In the case of wall mounting, the swivel axis
should preferably be positioned horizontally. For
other swivel directions, cable downwards (swivel
axis vertical).
Cover the screw heads using the provided plastic
caps.
5. Electrical Connection
Push the cap
over the connecting chamber
until all four corners clip into place.
Clip the swivel lever
bush
, bending the retaining arms apart.
into position in the bearing